The above pin-out is applicable to all the ow meters and controllers ordered with the
industrial connector. The availability of different output signals depends on the ow
meter options ordered.
The locking industrial connector is standard on all CSA/ATEX approved devices.
RS-485 is not available on CSA/ATEX approved devices.
Locking Industrial Connector Pin-Outs
If your Alicat Instrument was ordered with a Six Pin Locking Industrial
connection, please be sure to reference the following pin-out diagram.
Pin Function
1 Power In ( + )
2 RS-232TX / RS-485(+)
3 RS-232RX / RS-485(-)
4 Meters/Gauges = Remote Tare (Ground to Tare)
Controllers = Analog Set-Point Input
5 Ground (common for power, communications and signals)
6 Signal Out (Voltage or Current as ordered)
Male Connector: Cable Female Connector: Device